3.2.5.2 Disassemble Load-Case-Combinaton🔷

Many result components when queried for the minimum or maximum result for a load-case-combination at a specific position return the index of the corresponding load-case within the load-case-combination. This index can be used in combination with the "Disassemble Load Case Combination"-component to retrieve information regarding the load-case in question.

Figure 3.2.5.2.1 shows the component in action: After providing a model which contains the load-case-combination (LCC) in question its name may set via the "LCCName" input plug or selected via the drop-down menu at the bottom. The former overrides the latter. Load-cases within a load-case-combination are indexed starting at zero. Supplying "3" to input "LCInd" thus results in retrieval of the fourth load-case.

On the output side the model emerges unchanged, "LCText" outputs the textual representation of the load-case in question, "LCNames" the load-case names of which it is composed, "LCFactors" the factors with which they enter the load-case.

Last updated